Event Power Needs Checklist: Catering, DJ, Lights and More
A checklist of every power draw at a wedding or party, with questions for the caterer, DJ and lighting vendors and how to plan circuits for Chicago venues.

Power problems rarely show up in the planning meeting. They show up at 7:40 p.m., when the caterer's warmer, the DJ's speakers and the heaters all share a single breaker. A simple checklist, completed a few weeks before, prevents it. This guide gives you the questions, the math and a worksheet.
The basic math
Electrical load is measured in watts. Circuits are rated in amps.
Watts = volts × amps. In the United States, outlets provide 120 volts. A 15-amp circuit provides 1,800 watts at most, and a 20-amp circuit provides 2,400 watts. For loads that run for hours, plan to stay under about 80 percent of the rating, which is 1,440 watts on a 15-amp circuit and 1,920 watts on a 20-amp circuit.
Several outlets in a room may share one breaker. Venues usually know which ones, so ask.
Sample wattages in the figure are illustrative. Use the numbers from your vendors.
The checklist
| Who | What to ask | Why |
|---|---|---|
| Caterer | Which equipment needs power? How many outlets and what amps? Do they bring propane? | Warmers, urns and refrigeration are heavy loads |
| Bar | Ice machines, blenders, refrigeration | Often forgotten |
| DJ or band | Total watts for sound and lights, number of outlets, preferred circuit | Audio wants a clean circuit |
| Lighting vendor | Total watts, controller location, daisy chain limits | See uplights |
| Photo booth | Watts and outlet near the booth | Printers and lights add up |
| Heating and cooling | Watts per unit, number of units | See fans and coolers |
| AV and screens | Projector, TV, laptop | See projector sizing |
| Florist and decor | Lit signs, neon, fountain | Small but real |
| Rental company | Tent lights, heaters, lamps | Part of the order |
Ask the venue
- How many outlets are available, and what circuits are they on?
- What are the amp ratings and are any GFCI protected?
- Is there a house electrician? Do outside vendors need to use them?
- Is a generator allowed? Where can it be placed? See quiet generator placement.
- Are there hours when power is off?
- Who can I call if a breaker trips?
Get the answers in writing and send them to every vendor.
Make the plan
- 1Step 1List all devicesby vendor with watts.
- 2Step 2Total each areakitchen, bar, stage, dining.
- 3Step 3Map to circuitswith the venue's help.
- 4Step 4Move heavy loadsto dedicated circuits.
- 5Step 5Add a generatorif the venue cannot meet the load.
Outdoor and tent events
In tents and yards, power often comes from a generator or a long run from a house. Size the generator using generator sizing. Use appropriate cords as described in extension cord safety and cords on grass. Check heating needs with tent heater vs patio heater.
Common surprises
- Everything on one breaker. Several outlets in a room often share one circuit.
- Caterer needs more than they said. Ask again two weeks before.
- Outlets are far away. Long cords reduce power; use heavier gauge.
- The venue turns off power at a set hour. Ask.
- Phone charging. A charging station is a small load, but a long cord run.
- Overnight loads. Refrigeration should not be on the same circuit as heaters.
- 15 A circuit maximum
- 1,800 W
- 15 A circuit maximum
- Safe continuous load
- 1,440 W
- Safe continuous load
- 20 A circuit maximum
- 2,400 W
- 20 A circuit maximum
- 20 A safe continuous
- 1,920 W
- 20 A safe continuous
- US outlet voltage
- 120 V
- US outlet voltage
- Reconfirm with vendors
- 2 weeks
- Reconfirm with vendors
Chicago notes
Many older Chicago buildings have limited circuits per room, and downtown venues may charge for extra power or require union electricians. Suburban banquet halls vary widely. For a park or forest preserve, ask the district whether outlets are available at your pavilion at all.
Frequently asked questions
How much power do I need for a wedding?
How many watts are in a standard outlet?
Can I plug the DJ into the same outlet as the caterer?
Do I need a generator?
What if the breaker trips?
Who should I ask about power?
Get power right before the day
Book a free 15-minute seating call and we will help plan the full rental list, or request a quote.
- Lighting & Power
- Checklist
- Planning
Battery-Powered Event Lighting: Options, Run Times and Charging Plan
Tent Heater vs Patio Heater: Which One Works for Your Event?
Fans and Evaporative Coolers for Summer Events: What Works in Chicago
Monogram and Gobo Projection: Sizes, Surfaces and What to Order